Special application M/G FX


Download PDF

ELECTRONIC LOAD LIMITER

The load limiters "M/G FX" series are extremely small and easy to handle, with aluminum load cell body with high protection degree (IP 67) for application in any environment.

"M/G FX" applied to the fixed head rope and the simple installation procedure takes only a few minutes.

Mod. FX1 FX2 FX3
Material Alluminio Alluminio Ac. INOX
Calib
Field (kg)
100-3000 3001-10000 10001-15000
Max rope
dim.
5-18 12-30 18-40
Dim.
(cm)
240x84x80 240x84x80 240x84x80
Weight
(kg)
3,5 4 6


Zoom Click to enlarge image

Special application M/G FX Special application M/G FX Schema
Analog Output

Technical Specifications

MaterialStainless steel/Aluminium
Nominal load3000, 10000, 15000 kg
Supply voltageMaximum 15 V dc (option 24 V dc)
OutputOptional: 0-10V or 4-20mA
Operating temperature-20 / +70°C (-4 / +158°F)
Protection classIP 67
Dimensions (mm)240 x 84 x 80 mm - 9.4 x 3.3 x 3.1 in (LxWxH)
Average error≤ 1 % of full scale
Standard cable length5 m – 4 x 0,25 (shield not connected to the load cell body)
For the complete and latest technical specifications, please refer to the technical data sheet which can be downloaded here:
Download PDF

Connections

TypeSHIELDED CABLE 4C R5 PUR 4X0,25
Length5 m (body lead cell not connected shield)
Red+ IN
Black- IN
Green+ OUT
White- OUT
Connections  Special application M/G FX

MOUNTING OF THE LOAD CELL

General precautions to be followed in the installation and assembly of load cells:

  • Follow the direction of application of force on the load cell
  • Do not exceed the limits of the temperature as indicated in the data sheet
  • Do not remove labels from the load cell
  • Adequately protect the cables with sleeves or channels
  • Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
  • Do not carry out any welding on the mechanical structure after mounting the load cell
  • Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
  • In case of vibration or dynamic loads product the load cells with puffers / shock absorbers
  • Protect load cell from any dust accumulation with any appropriate means